Extend/retract touch probe |
| M23 | Measure current tool |
| M24 | Remeasure and store Z Reference in Parameter 942 |
| M31 | Signal Nanovea controller to start data collection |
| M32 | Signal Nanovea controller to stop data collection |
| M40 | Extend touch probe |
| M41 | Retract touch probe |
| M61 | Probe center of die, set XYZ part zero there |
| M62 | Probe surface of die, set Z part zero there |
| Parameter | Typical value | Meaning |
|---|---|---|
| 940 | 1.675 | X spacing between touch probe centerline and spindle centerline |
| 942 | -3.9749 | Z Reference for tool measurement (distance down from home to trip touch probe on tool pad) |
| 943 | 0.000 | Y spacing between touch probe centerline and spindle centerline |
| Location | Use |
|---|---|
| WCS #1 - #6 (G54-G59) |
Available for machining parts |
| Return Point #3 (G30 P3) |
Touch probe aligned over tool touch pad |
| Return Point #4 (G30 P4) |
Spindle aligned over tool touch pad (tool-measuring start point) |